Description

 Reliable Automatic Power Switching: Seamlessly transfers selected circuits from utility power to backup power during an outage—no manual intervention required.
• 50A Bus Bar with 30A Backup Support: Built with a 50A-rated bus bar for full-capacity handling of normal utility power, while safely limiting backup power to 30A. Compatible with most solar generators, battery backup systems, and gas generators. Supports 120V, 120/240V, and 120/208V systems, and is fully compatible with AFCI and GFCI breakers.
• Essential Circuit Coverage: Manages up to 16 circuits, allowing essential appliances and systems to stay powered during outages.
• Durable, Heavy-Duty Enclosure: Built with a rugged enclosure designed for dependable performance and long-term reliability in demanding installation environments.
• Complete Connection & Control System: Includes a L14-30P 30A inlet and 30A power cord, plus a centralized control console for system monitoring, testing, and manual power source override.
 Certified for Safety & Code Compliance: Meets rigorous safety and performance standards including UL 1008 and CAN/CSA C22.2 No. 178.1, with documentation showing compliance under ISO/IEC Guide 17067

Read More Read Less

Nature's Generator

30A Automatic Generator Transfer Switch

Precio de venta$399.99
Options:30A Automatic Transfer Switch

SPECIFICATIONS

Specification
Power Rating: 30A
System Voltage: 120 V~ (L-N) / 208V~ (L-L) / 240V~ (L-L)
Number of Spaces: 8 spaces
Number of Circuits: Expandable to 16 circuits with tandem breakers

Dimension and Weight
600*360*160mm
(22 3/4*14 1/4*6 1/2 inches)
48 lbs(21.6 kg)

Certification* CAN/CSA C22.2 No. 178.1
UL 508A
UL1008

SHIPPING & DELIVERY

Fast Processing

  • Processing/Fulfillment: typically 6–12 business days (excluding weekends/holidays and unforeseen vendor/carrier delays).
  • Once fulfilled, your order moves to carrier pickup and scheduling.

Quick Delivery

  • Transit time (after shipment): typically 3–12 business days, depending on location and carrier routing.
  • Freight/LTL delivery: ships palletized and is typically curbside delivery.
  • Adult presence/signature: an adult 18+ may be required for delivery and/or signature.

What delivery includes:

  • Included: curbside drop-off (end of driveway/curb).
  • Not included: inside delivery, stairs, placement, uncrating, assembly/installation.

Extra services & fees:

  • Optional accessorials (when available) may add charges: liftgate, residential delivery, and limited/remote access

Missed delivery / access issues:

  • If delivery can’t be completed due to access limits, missed appointments, or inability to unload, you may be responsible for redelivery/storage fees charged by the carrier.

Order Tracking

  • You’ll receive a tracking PRO # once your order ships.
  • Tracking may take 24–72 hours to update after pickup/label creation.
  • After the shipment leaves the warehouse, the carrier controls routing, timing, and scheduling.
  • When it arrives at the local terminal, the carrier typically contacts you to schedule delivery.

Need help? support@garagerebel.com

⚠️ Delivery Inspection (IMPORTANT)⚠️ 

Inspect BEFORE signing the delivery receipt/BOL.

If you see damage or missing items:

  1. Take photos/video immediately (packaging + labels + product).
  2. Write damage notes on the receipt BEFORE signing
  • Example: “pallet crushed, box torn, dented frame, possible concealed damage.”
  1. If damage is major, refuse delivery and contact us immediately.

Important: If you sign without noting damage, it may limit or void the ability to file a freight damage claim.

Concealed damage

  • Report within 48 hours of delivery.
  • Keep all packaging for inspection.

Send photos/video + delivery paperwork to: returns@garagerebel.com

Full details: Shipping Policy

RETURN & REFUND

As an authorized dealer of Nature’s Generator, returns follow their return and warranty guidelines. Returns must be pre-authorized.

RETURN AUTHORIZATION (REQUIRED)

  • Email returns@garagerebel.com to request a Return Authorization (RMA/RAN) and instructions.
  • Returns shipped without authorization may be refused.

Include in your email:

  • Order number
  • Item name/model (and SKU/serial if applicable)
  • Reason for return
  • Photos/video (if applicable)

RETURN WINDOW & CONDITIONS
Returns may be accepted within 30 days of purchase (if approved).

Items must be:

  • Uninstalled / unused
  • In like-new condition
  • In original packaging with all parts, manuals, and accessories
  • Serial numbers must match (when applicable)
  • Additional fees may apply if an item is opened, incomplete, damaged, or missing packaging.

RETURN SHIPPING & FEES

  • Return shipping is the customer’s responsibility unless it's due to a defective product, shipping delay and/or damaged package.For returns due to other reasons (e.g., change of mind, incorrect item ordered), return shipping costs and handling fees will be deducted from the refund.
  • Outbound shipping costs may be deducted from the refund (even if “free shipping” was offered).
  • A 15% restocking fee may apply for returns not related to defect/warranty (including refused shipments).
  • 3% merchant processing fee will be deducted from all refunds to cover non-refundable transaction fees charged by payment processors (e.g., credit card, PayPal). These fees are incurred at the time of purchase and cannot be recovered once the transaction is processed.
  • Please allow an additional 7–10 business days for your bank or credit card provider to process the refund.

NOT ELIGIBLE FOR RETURN / CREDIT

  • Requests after 30 days
  • Used, installed, or improperly packaged items
  • Damage due to misuse, incorrect installation, or environmental exposure
  • Items missing parts/accessories/manuals or altered/defaced items
  • Items without proof of purchase
  • Products that have been installed.

CANCELLATIONS

  • Orders that have not shipped may be canceled with a 5% cancellation fee (payment processing cost).
  • If the order has already been shipped, cancellation is no longer possible, it must follow the return policy.

Returns/RMAs: returns@garagerebel.com
More details: See full details: Return Policy

FAQ

How does an Automatic Transfer Switch work?
An ATS automatically detects a power outage and switches your home to backup power without manual intervention.

Do ATS models support 120V and 240V systems?
Yes, compatible ATS models support both 120V and 120V/240V systems depending on configuration.

Can I still control the switch manually if needed?
Yes, select ATS models include a manual override for added flexibility and safety.

Is professional installation required for ATS units?
Yes, ATS installation must be performed by a licensed electrician to meet electrical codes and safety standards.

Description

 Reliable Automatic Power Switching: Seamlessly transfers selected circuits from utility power to backup power during an outage—no manual intervention required.
• 50A Bus Bar with 30A Backup Support: Built with a 50A-rated bus bar for full-capacity handling of normal utility power, while safely limiting backup power to 30A. Compatible with most solar generators, battery backup systems, and gas generators. Supports 120V, 120/240V, and 120/208V systems, and is fully compatible with AFCI and GFCI breakers.
• Essential Circuit Coverage: Manages up to 16 circuits, allowing essential appliances and systems to stay powered during outages.
• Durable, Heavy-Duty Enclosure: Built with a rugged enclosure designed for dependable performance and long-term reliability in demanding installation environments.
• Complete Connection & Control System: Includes a L14-30P 30A inlet and 30A power cord, plus a centralized control console for system monitoring, testing, and manual power source override.
 Certified for Safety & Code Compliance: Meets rigorous safety and performance standards including UL 1008 and CAN/CSA C22.2 No. 178.1, with documentation showing compliance under ISO/IEC Guide 17067

Read More Read Less